335
Loop Resil-
iency Cir-
cuit (LRC):
Circuits within the SM modules which provide loop resiliency in the
event of a drive failing or being unplugged.
Low Voltage
Differential
(LVD)
LVD is a method of powering SCSI cables that will be formalized in the
SCSI-3 specifications. LVD uses less power than the current differential
drive (HVD), is less expensive, and allows for higher speeds such as
those of Ultra2 SCSI. LVD requires 3.3 volts (versus 5 volts for HVD).
LRC I/O mod-
ule
A plug-in Input/Output module used to connect the internal FC-AL
channels from the EF2800 backplane to the rear of the enclosure.
Management
Informa-
tion Base
(MIB)
A MIB is a database of managed objects accessed by network
management protocols. An SNMP MIB is a set of parameters that an
SNMP management station can query or set in the SNMP agent of a
network device (such as a router).
mapping table A mapping table is a table indexed by sequential LUN values. The values
indicate select bus:target:LUN devices. Mapping tables are used by
some routers to perform FC-to-SCSI operations by default.
Module (drive
carrier,
power sup-
ply/cool-
ing, storage
manager)
A module is a power supply, disk drive or electronics unit held in a
carrier that plugs into a bay inside the enclosure. An EF2800 enclosure
can contain sixteen drive carrier modules, two power supply/cooling
modules and two Storage Manager modules.
Operating sys-
tem
The software running the host computer. For example, on PCs it is
often Windows 95/98, Windows NT or OS/2 and on Hewlett-Packard
machines it could be HP-UX.
other control-
ler or SM
The opposite controller or Storage Module (SM) from the one currently
being used (that is, not the local controller or SM that you are
connected to) is referred to as the other.
Vue de la page 357
1 2 ... 353 354 355 356 357 358 359 360 361 362 363 ... 380 381

Commentaires sur ces manuels

Pas de commentaire

Manhattan 158251 manuali

Manuali dei proprietari e guide per l'utente per Schede/adattatori di rete Manhattan 158251.
We fornisce 1 manuali pdf Manhattan 158251 per scaricare gratuitamente in base al tipo di documento: Scheda Tecnica






Più prodotti e manuali per Schede/adattatori di rete Manhattan

Modelli Tipo di Documento
171557 Scheda Tecnica   Manhattan 171557, 2 pagine
158039 Scheda Tecnica   Manhattan 158039, 2 pagine
176576 Scheda Tecnica   Manhattan Serial PC Card, 2 pagine
515016 Scheda Tecnica   Manhattan FireWire 400 ExpressCard/34, 2 pagine
176781 Scheda Tecnica   Manhattan Tarjeta Serial PCI, 2 pagine
167048 Scheda Tecnica   Manhattan 167048, 2 pagine
158237 Scheda Tecnica   Manhattan 158237, 2 pagine
176996 Scheda Tecnica   Manhattan Tarjeta PCI FireWire, 2 pagine
158152 Scheda Tecnica   Manhattan 158152, 2 pagine
170598 Scheda Tecnica   Manhattan IDE - SATA 150, 2 pagine
158008 Scheda Tecnica   Manhattan ExpressCard/34, 2 pagine
160476 Manuale Utente   Manhattan 160476, 8 pagine
158046 Manuale Utente   Manhattan 158046, 8 pagine
160483 Manuale Utente   Manhattan 160483 [en] , 8 pagine
150972 Manuale Utente        Manhattan 150972, 12 pagine
158299 Manuale Utente   Manhattan 158299, 4 pagine
160513 Manuale Utente   Manhattan 160513, 4 pagine
177351 Guida di Installazione   Manhattan 177351, 2 pagine
160414 Manuale Utente   Manhattan 160414, 8 pagine
158176 Manuale Utente   Manhattan 158176, 8 pagine